Material Properties and Selection
Index of refraction goes from 1.4 (fluorides) to 4.0 (germanium), which affects the focal length. BK7 glass (n=1.517) works for visible light applications. Fused silica lets UV light pass through. Germanium works for infrared light from 2-16μm.
Abbe number shows how much the material separates colors. Higher numbers (above 55, crown glass) separate colors less. Lower numbers (below 50, flint glass) separate colors more. For single-color laser applications, Abbe number is less important than for regular imaging.
Laser damage threshold is the maximum power level before the surface gets damaged. High-power applications need materials and coatings that can handle your laser power. Fused silica usually resists laser damage better than regular optical glass.